Dose-resolved degrader profiling: dBET1 in Jurkat cells
Eleven doses, about 10,000 proteins per sample and a dose–response curve for every protein. Read the note
See everything your degrader removes, how quickly and completely it works, and how it gets there, with proteomics built for targeted protein degradation.
Global proteomics measures thousands of proteins in each sample, showing what else your degrader removes, including neosubstrates.
Targeted PRM assays track your target across doses and time points, for precise degradation curves.
Ubiquitylome and interaction profiling show where the target is ubiquitinated and which E3 ligase partners are recruited.
Methods
Each method answers a different question about your compound, and they’re designed to be used together as a program matures.
What it measures
Protein abundance across the proteome, by TMT (up to 18 samples per plex) or DIA (high throughput).
Best for
Selectivity, off-target degradation and neosubstrate discovery, including for molecular glues.
What it measures
Your target and control peptides, quantified by PRM against heavy internal standards.
Best for
Dose response and time courses, ranking compounds and in vivo samples.
What it measures
Ubiquitination sites across the proteome, enriched through their diGly remnant.
Best for
Confirming the target is ubiquitinated, mapping sites and specificity screening.
What it measures
The proteins pulled down with your target or E3 ligase, with and without compound, by quantitative IP-MS.
Best for
Confirming ternary complex formation and finding new interaction partners.
Why combine them
Degrader programs often move through these methods in sequence. DIA screens compounds broadly for selectivity, TMT gives precise, focused validation, and PRM measures a defined panel of targets with the highest sensitivity as a program approaches the clinic. Ubiquitylome and interaction profiling explain the mechanism along the way.
Because all four run in one lab on the same platforms, results carry across stages without re-establishing methods with a new provider.
From first screen to final candidate, one lab and one dataset lineage.
Case study
We treated Jurkat cells with the BET degrader dBET1 at 11 concentrations plus vehicle for 4 hours, in four biological replicates, and quantified about 10,000 proteins per sample by Orbitrap Astral DIA: 96 injections from one 96-well plate.
01 · Selectivity
We fit a dose–response curve to every protein and calibrated its significance against data with shuffled dose labels, so only real dose effects pass. BRD2, BRD3 and BRD4 were the only proteins whose loss could be attributed to dBET1.
The cereblon neo-substrates IKZF3, ZFP91 and GSPT1 were quantified in every sample and showed no dose-dependent change.

02 · Potency
BRD2, BRD3 and BRD4 fell with similar potency, with half-maximal degradation at 103–117 nM and 81–86% maximal loss relative to vehicle. At 1 µM, 17% of BRD4 remained.
BRD3 and BRD4 rose again at the top dose. We report that rebound with the data, without assigning a cause the design can’t support.

03 · Rigor
Because the vehicle concentration rose with dose, some proteins produced dose–response curves of their own. Placing the vehicle control on each curve showed that five responders, including NAB2, NR4A1 and ETS2, followed the vehicle rather than dBET1.
Below the per-protein threshold, 291 proteins, many of them mitochondrial, declined together at the top of the dose range, most steeply at 1–4 µM. We report both findings, and now recommend holding DMSO constant across doses.

Read the full study, with methods and every figure. Dose-resolved degrader profiling: dBET1 in Jurkat cells
How it works
Everything runs in 96-well format with automated sample preparation, in our Framingham laboratory.
We help plan doses, time points, controls and replicates before any sample is committed.
Cells treated across your dose series and time points. Cell culture available in house.
Proteins extracted and digested on automated, plate-based workflows.
DIA, TMT or PRM, chosen for the question: breadth, precision or sensitivity.
Quantification, QC and statistics, with degradation and selectivity results summarized.
Processed tables, a methods and summary report, and a consultation on what the data shows.
Specifications
Proteins per sample
More than 10,000
Throughput
48 samples per day
Best for
Screening many compounds, doses or time points
Proteins per sample
More than 9,500
Throughput
Up to 18 samples per plex, measured together
Best for
Precise, focused validation with no missing values
Proteins per sample
Your target panel
Throughput
High throughput; new assays about 10 weeks to develop
Best for
Sensitive degradation curves and in vivo samples
Evidence
Eleven doses, about 10,000 proteins per sample and a dose–response curve for every protein. Read the note
Hansen JD, et al. Read more
Ubiquitination sites quantified proteome-wide, including PROTAC specificity screening. Read the note
See all publications tagged with this service on our Reference page. Browse related publications
Tell us about your compounds, targets and samples. We’ll recommend the right combination of methods for where your program is now.