Opens in a new tab

Degrader profiling for PROTACs and molecular glues

See everything your degrader removes, how quickly and completely it works, and how it gets there, with proteomics built for targeted protein degradation.

>10,000
proteins measured per sample by DIA
4
complementary methods, from selectivity to mechanism
48
samples per day on the Orbitrap Astral

What it answers

Is it selective?

Global proteomics measures thousands of proteins in each sample, showing what else your degrader removes, including neosubstrates.

How fast, and how far?

Targeted PRM assays track your target across doses and time points, for precise degradation curves.

How does it work?

Ubiquitylome and interaction profiling show where the target is ubiquitinated and which E3 ligase partners are recruited.

Methods

Four ways to profile a degrader

Each method answers a different question about your compound, and they’re designed to be used together as a program matures.

Discovery · unbiased

Global selectivity

What it measures

Protein abundance across the proteome, by TMT (up to 18 samples per plex) or DIA (high throughput).

Best for

Selectivity, off-target degradation and neosubstrate discovery, including for molecular glues.

  • Unbiased, proteome-wide view
  • More than 10,000 proteins per sample by DIA, or 18 samples measured together by TMT
Targeted · quantitative

Degradation kinetics

What it measures

Your target and control peptides, quantified by PRM against heavy internal standards.

Best for

Dose response and time courses, ranking compounds and in vivo samples.

  • Sensitive and precise
  • Linear range extended at least 10-fold over discovery methods
PTM · mechanism

Ubiquitylome

What it measures

Ubiquitination sites across the proteome, enriched through their diGly remnant.

Best for

Confirming the target is ubiquitinated, mapping sites and specificity screening.

  • Site-level resolution
  • Thousands of sites per study with no missing values
Interactions · mechanism

E3 and ternary complex interactions

What it measures

The proteins pulled down with your target or E3 ligase, with and without compound, by quantitative IP-MS.

Best for

Confirming ternary complex formation and finding new interaction partners.

  • Works from as few as 5 million cells or 20 µg of protein
  • Up to 18 conditions compared together

Why combine them

One program, four views

Degrader programs often move through these methods in sequence. DIA screens compounds broadly for selectivity, TMT gives precise, focused validation, and PRM measures a defined panel of targets with the highest sensitivity as a program approaches the clinic. Ubiquitylome and interaction profiling explain the mechanism along the way.

Because all four run in one lab on the same platforms, results carry across stages without re-establishing methods with a new provider.

From first screen to final candidate, one lab and one dataset lineage.

Case study

dBET1 in Jurkat cells: one plate, a curve for every protein

We treated Jurkat cells with the BET degrader dBET1 at 11 concentrations plus vehicle for 4 hours, in four biological replicates, and quantified about 10,000 proteins per sample by Orbitrap Astral DIA: 96 injections from one 96-well plate.

01 · Selectivity

Three responders among 10,145 proteins

We fit a dose–response curve to every protein and calibrated its significance against data with shuffled dose labels, so only real dose effects pass. BRD2, BRD3 and BRD4 were the only proteins whose loss could be attributed to dBET1.

The cereblon neo-substrates IKZF3, ZFP91 and GSPT1 were quantified in every sample and showed no dose-dependent change.

10,145
proteins with a dose–response curve
3
dBET1-dependent responders: BRD2, BRD3, BRD4
Scatter plot of 10,145 proteins by maximum change against dose-response significance; BRD2, BRD3 and BRD4 highlighted in blue above the significance threshold.
Each point is one protein: its largest change across the dose series against curve significance. Blue: dBET1-dependent. Orange: tracks the vehicle or not attributable.

02 · Potency

Potency and depth for every BET protein

BRD2, BRD3 and BRD4 fell with similar potency, with half-maximal degradation at 103–117 nM and 81–86% maximal loss relative to vehicle. At 1 µM, 17% of BRD4 remained.

BRD3 and BRD4 rose again at the top dose. We report that rebound with the data, without assigning a cause the design can’t support.

113 nM
BRD4 DC₅₀ at 4 h (95% CI 93–134)
81–86%
maximal loss of BRD2, BRD3 and BRD4
Dose-response curves for BRD2, BRD3 and BRD4 falling from about 100% to 15–20% of vehicle, with DC50 values of 103, 117 and 113 nM.
BRD2, BRD3 and BRD4 fall with similar potency. Mean ± SD of four biological replicates, with four-parameter fits.

03 · Rigor

Compound effects, separated from vehicle effects

Because the vehicle concentration rose with dose, some proteins produced dose–response curves of their own. Placing the vehicle control on each curve showed that five responders, including NAB2, NR4A1 and ETS2, followed the vehicle rather than dBET1.

Below the per-protein threshold, 291 proteins, many of them mitochondrial, declined together at the top of the dose range, most steeply at 1–4 µM. We report both findings, and now recommend holding DMSO constant across doses.

5
changes traced to the vehicle, not dBET1
291
proteins declining together at the highest doses
Dose-response curves for NAB2, NR4A1 and ETS2 falling steeply with dose, with the vehicle control point sitting at the high-dose level.
NAB2, NR4A1 and ETS2 fall steeply with dose, but the vehicle control (square) sits with the highest doses, so these changes cannot be attributed to dBET1.

Read the full study, with methods and every figure. Dose-resolved degrader profiling: dBET1 in Jurkat cells

How it works

How a degrader study runs

Everything runs in 96-well format with automated sample preparation, in our Framingham laboratory.

  1. 1

    Design

    We help plan doses, time points, controls and replicates before any sample is committed.

  2. 2

    Treat

    Cells treated across your dose series and time points. Cell culture available in house.

  3. 3

    Prepare

    Proteins extracted and digested on automated, plate-based workflows.

  4. 4

    Acquire

    DIA, TMT or PRM, chosen for the question: breadth, precision or sensitivity.

  5. 5

    Analyze

    Quantification, QC and statistics, with degradation and selectivity results summarized.

  6. 6

    Deliver

    Processed tables, a methods and summary report, and a consultation on what the data shows.

Specifications

What to expect

Global (DIA)

Proteins per sample

More than 10,000

Throughput

48 samples per day

Best for

Screening many compounds, doses or time points

Global (TMT)

Proteins per sample

More than 9,500

Throughput

Up to 18 samples per plex, measured together

Best for

Precise, focused validation with no missing values

Targeted (PRM)

Proteins per sample

Your target panel

Throughput

High throughput; new assays about 10 weeks to develop

Best for

Sensitive degradation curves and in vivo samples

Every project includes

  • A results table with DC50, Dmax, significance and response class for every protein
  • Curve plots for every responder and any proteins you name, plus a selectivity map and a CRBN neo-substrate panel
  • A QC report, raw files, processed output and the analysis code
  • A consultation on what the data shows

Evidence

Related work

Technical note

Dose-resolved degrader profiling: dBET1 in Jurkat cells

Eleven doses, about 10,000 proteins per sample and a dose–response curve for every protein. Read the note

Customer program · J Med Chem 2021

CC-90009: A Cereblon E3 Ligase Modulating Drug That Promotes Selective Degradation of GSPT1 for the Treatment of Acute Myeloid Leukemia

Hansen JD, et al. Read more

Technical note

Ubiquitylome profiling

Ubiquitination sites quantified proteome-wide, including PROTAC specificity screening. Read the note

See all publications tagged with this service on our Reference page. Browse related publications

Developing a degrader?

Tell us about your compounds, targets and samples. We’ll recommend the right combination of methods for where your program is now.